DC/DC Converter
TEN 40WIN Series, 40 Watt
•
Highest power density: 40 W
in 1” x 2” x 0.4” package
•
•
•
•
•
Ultra wide 4:1 input range
•
•
I/O isolation 1500 VDC
•
3-year product warranty
Excellent efficiency up to 90 %
Output voltage adjustable
Remote On/Off
UL 62368-1 IEC 62368-1
Protection against short circuit
and over voltage
Operating temperature range
–40°C to +75°C
The TEN 40WIN Series is a new range of isolated high performance DC/DC-converter modules. Due to the very high efficiency of up to 90% these 40 W
converters come with a footprint of only 1.0” x 2.0”. The 12 models have an ultra wide 4:1 input voltage range and a tight output voltage regulation. The output voltage is adjustable by external resistor. Remote On/Off and protection
against overpower and over voltage are standard features of these converters.
Typical applications are in mobile equipment, instrumentation, distributed power architectures in communication and industrial electronics and everywhere
where space on the PCB is limited.
Models
Order Code
Input Voltage
Range
TEN 40-2410WIN
TEN 40-2411WIN
TEN 40-2412WIN
TEN 40-2413WIN
TEN 40-2415WIN
TEN 40-2422WIN
TEN 40-2423WIN
TEN 40-4810WIN
TEN 40-4811WIN
TEN 40-4812WIN
TEN 40-4813WIN
TEN 40-4815WIN
TEN 40-4822WIN
TEN 40-4823WIN
9 - 36 VDC
(24 VDC nom.)
18 - 75 VDC
(48 VDC nom.)
Output 1
Output 2
Vnom
Imax
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
+12 VDC
+15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
+12 VDC
+15 VDC
8'000 mA
8'000 mA
3'330 mA
2'670 mA
1'670 mA
1'670 mA
1'330 mA
8'000 mA
8'000 mA
3'330 mA
2'670 mA
1'670 mA
1'670 mA
1'330 mA
Vnom
Efficiency
Imax
–12 VDC
–15 VDC
1'670 mA
1'330 mA
–12 VDC
–15 VDC
1'670 mA
1'330 mA
typ.
89 %
90 %
89 %
89 %
91 %
88 %
88 %
89 %
90 %
90 %
90 %
91 %
88 %
88 %
Options
TEN-HS4
- Optional Heat Sink: www.tracopower.com/products/ten-hs4.pdf
TEN-HS6
- Optional Heat Sink: www.tracopower.com/products/ten-hs6.pdf
www.tracopower.com
September 20, 2023
Page 1 / 5
TEN 40WIN Series, 40 Watt
Input Specifications
Input Current
24 Vin models: 90 mA typ. (3.3 Vout model)
90 mA typ. (5 Vout model)
95 mA typ. (12 Vout model)
105 mA typ. (15 Vout model)
115 mA typ. (24 Vout model)
65 mA typ. (12 / -12 Vout model)
65 mA typ. (15 / -15 Vout model)
48 Vin models: 55 mA typ. (3.3 Vout model)
55 mA typ. (5 Vout model)
60 mA typ. (12 Vout model)
65 mA typ. (15 Vout model)
75 mA typ. (24 Vout model)
45 mA typ. (12 / -12 Vout model)
45 mA typ. (15 / -15 Vout model)
24 Vin models: 1'240 mA max. (3.3 Vout model)
1'850 mA max. (5 Vout model)
1'870 mA max. (12 Vout model)
1'870 mA max. (15 Vout model)
1'835 mA max. (24 Vout model)
1'890 mA max. (12 / -12 Vout model)
1'890 mA max. (15 / -15 Vout model)
48 Vin models: 620 mA max. (3.3 Vout model)
930 mA max. (5 Vout model)
930 mA max. (12 Vout model)
930 mA max. (15 Vout model)
920 mA max. (24 Vout model)
950 mA max. (12 / -12 Vout model)
950 mA max. (15 / -15 Vout model)
24 Vin models: 50 VDC max. (100 ms max.)
48 Vin models: 100 VDC max. (100 ms max.)
24 Vin models: 8.3 VDC typ.
48 Vin models: 16.5 VDC typ.
24 Vin models: 30 mAp-p typ.
48 Vin models: 20 mAp-p typ.
24 Vin models: 8'000 mA (slow blow)
48 Vin models: 4'000 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal LC-Type
- At no load
- At full load
Surge Voltage
Under Voltage Lockout
Reflected Ripple Current
Recommended Input Fuse
Input Filter
Output Specifications
Output Voltage Adjustment
See application note:
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
- Voltage Balance
(symmetrical load)
single output models:
dual output models:
single output models:
dual output models:
dual output models:
–10% to +20% (24 Vout models)
±10% (other models)
(single output models only)
(By external trim resistor)
www.tracopower.com/overview/ten40win
Output power must not exceed rated power!
±1% max.
0.5% max.
0.5% max.
0.5% max.
1% max. (Output 1)
1% max. (Output 2)
2% max.
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 2 / 5
TEN 40WIN Series, 40 Watt
Ripple and Noise
(20 MHz Bandwidth)
- single output
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
- dual output
Capacitive Load
- single output
- dual output
Minimum Load
- single output
- dual output
Temperature Coefficient
Start-up Time
Short Circuit Protection
Output Current Limitation
Transient Response
- Response Deviation
- Response Time
100 mVp-p max. (w/ 1µF MC || 10µF TC)
100 mVp-p max. (w/ 1µF MC || 10µF TC)
150 mVp-p max. (w/ 1µF MC || 10µF TC)
150 mVp-p max. (w/ 1µF MC || 10µF TC)
150 mVp-p max. (w/ 1µF MC || 10µF TC)
150 / 150 mVp-p max. (w/ 1µF MC || 10µF TC)
150 / 150 mVp-p max. (w/ 1µF MC || 10µF TC)
21'000 µF max.
13'600 µF max.
2'400 µF max.
1'500 µF max.
600 µF max.
1'200 / 1'200 µF max.
750 / 750 µF max.
0 % of Iout max.
0 % of Iout max.
0 % of Iout max.
0 % of Iout max.
0 % of Iout max.
9 % of Iout max.
8 % of Iout max.
±0.02 %/K max.
30 ms max.
Continuous, Automatic recovery
150% typ. of Iout max.
3% typ. / 5% max. (75% to 100% Load Step)
250 µs typ. (75% to 100% Load Step)
Safety Specifications
Safety Standards
CSA-C22.2, No. 60950-1
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
www.tracopower.com/overview/ten40win
PD 3
Not mains connected
- IT / Multimedia Equipment
- Certification Documents
Pollution Degree
Over Voltage Category
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
External filter proposal:
EMS Immunity
- Electrostatic Discharge
Air:
Contact:
- RF Electromagnetic Field
- EFT (Burst) / Surge
- Conducted RF Disturbances
- PF Magnetic Field
Continuous:
EN 55032 class A (with external filter)
FCC Part 15 class A (with external filter)
EN 55032 class A (with external filter)
FCC Part 15 class A (with external filter)
www.tracopower.com/overview/ten40win
EN 55024 (IT Equipment)
EN 55035 (Multimedia)
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 3 A/m, perf. criteria A
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 3 / 5
TEN 40WIN Series, 40 Watt
General Specifications
Relative Humidity
Temperature Ranges
Power Derating
Over Temperature
Protection Switch Off
Cooling System
Remote Control
95% max. (non condensing)
–40°C to +75°C
+105°C max.
–50°C to +125°C
Depending on model
See application note: www.tracopower.com/overview/ten40win
110°C typ.
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
- Protection Mode
- Voltage Controlled Remote
- Off Idle Input Current
- Remote Pin Input Current
Altitude During Operation
Switching Frequency
Insulation System
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
Washing Process
- Input to Output, 60 s
- Input to Output, 1 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
Housing Material
Base Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
Thermal Impedance
Natural convection (20 LFM)
On: 3.5 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
2.5 mA max.
-0.5 to 0.5 mA
6'000 m max.
285 kHz typ. (PWM) (24 Vout models)
320 kHz typ. (PWM) (other models)
Functional Insulation
1'500 VDC
1'800 VDC
1'000 MΩ min.
1'500 pF typ.
330'000 h (MIL-HDBK-217F, ground benign)
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
Alu alloy, black anodized coating
Non-conductive FR4 (UL 94 V-0 rated)
Epoxy (UL 94 V-0 rated)
Copper Alloy (C6801)
Nickel (2.5 µm min.)
Gold (75 - 125 nm), glossy
Metal Case
PCB Mount
THD (Through-Hole Device)
2" x 1"
Lead-Free Wave Soldering
260°C / 10 s max.
30 g
12 K/W typ.
10 K/W typ. (with Heat Sink)
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
14ea9ef9-80c5-4478-895c-1762f23c29c8
- Case to Ambient
Environmental Compliance - REACH Declaration
- RoHS Declaration
- SCIP Reference Number
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/ten40win
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 4 / 5
TEN 40WIN Series, 40 Watt
3
Pinout
25.4 (1.00)
2.54
5
3.6 (0.14)
1.85 (0.073)
(0.400)
Bottom view
10.16
(0.400)
10.16
2
(0.400)
4
1
10.16
5.08
(0.200)
50.8 (2.00)
(0.100)
Outline Dimensions
6
Single
Dual
1
+Vin (Vcc)
+Vin (Vcc)
2
–Vin (GND)
–Vin (GND)
3
Remote On/Off
Remote On/Off
4
+Vout
+Vout
5
–Vout
Common
6
Trim
–Vout
5.5
(0.22)
h
45.72 (1.800)
Pin
Ø1.0 (Ø0.04)
h=11.0 (0.43) for 24 VDC output models
h=10.2 (0.40) for other models
Dimensions in mm (inch)
Tolerances: x.x ±0.25 (x.xx ±0.01)
x.xx ±0.13 (x.xxx ±0.005)
Pin diameter tolerances: x.x ±0.05 (x.xx ±0.002)
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. September 20, 2023
Page 5 / 5
很抱歉,暂时无法提供与“TEN 40-4823WIN”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+780.925791+96.87348
- 10+645.8229610+80.11404
- 25+624.5024925+77.46925
- 50+608.8402050+75.52635
- 100+593.57278100+73.63243
- 250+527.02084250+65.37669